Owens Corning

Owens Corning

Address:
1 Owens Corning Parkway
Toledo, OH 43659
USA
Phone: 1-800-GET-PINK®
Website:

Displaying 5 course(s).

  • Protected roof membrane assemblies (PRMAs), and vegetative roof assemblies (VRAs) in particular, place extreme requirements on the components below the surface, from waterproofing to insulation and everything in between. Each element must meet specific standards for energy efficiency and durability. This course reviews the benefits and design considerations of VRAs. It also describes the high-performance attributes of VRA components and defines the building code/performance standards and best specification practices for optimal fire, wind, thermal, and moisture performance.

             

     This course contains sustainable design information. See the course details page for more information.

     This course is ONLINE: SELF-PACED. Experience it on your own schedule, at your convenience.

  • A growing number of high-rise fire incidents around the world have raised awareness about the fire safety performance of taller structures. Timing for containing a high-rise fire is critical, as high numbers of occupants have limited means of escape. Vertical fire spread along the exterior facade may quickly overwhelm firefighters at ground level, especially if it advances to heights beyond the reach of their ground attack. This course looks at issues surrounding high-rise fires, how they spread, and how following building codes and proper material testing can lessen the risk or impact of these blazes.

             

     This course is ONLINE: SELF-PACED. Experience it on your own schedule, at your convenience.

  • This course explains the NFPA 285 test method, its origin, its procedures, when it is required, and design considerations necessary for compliance. Criteria in ASHRAE 90.1 for continuous insulation and air/water-resistive barriers are reviewed and identified as contributors to the rise of NFPA 285 requirements. The course also addresses code compliance in light of recent material changes, code changes, and additional testing.

             

     This course is part of one or more "Course Collections". Click here to view the details.

     This course is ONLINE: SELF-PACED. Experience it on your own schedule, at your convenience.


  • 1 hour 15 minutes  

    One of the most complex and least understood areas where fire can propagate is at the perimeter of a multistory building. Fire can spread not only from floor to floor via the edge-of-slab/curtain wall intersections but also along the exterior building enclosure where untested, combustible components are often installed. This program outlines best design practices for providing fire protection for building occupants per ASTM E2307 and ASTM E2874.

             

     This course is ONLINE: SELF-PACED. Experience it on your own schedule, at your convenience.

  • Insulation can help increase overall energy efficiency, minimize the spread of fire, manage risks associated with moisture and mold, and improve occupant comfort. Choosing the right insulation and putting it in the right location is becoming one of the most important decisions in design, construction, and retrofit. Reviewed in this course are the features, benefits, and design and installation considerations related to mineral wool continuous insulation.

             

     This course contains sustainable design information. See the course details page for more information.

     This course is ONLINE: SELF-PACED. Experience it on your own schedule, at your convenience.

Displaying 5 course(s).