Category: BUILDING CODE

Displaying 1 - 24 of 24 results.


  • ( ~ 1 hour ) 

    Plumbing design is highly regulated; improper design and installation can pose a serious health risk or result in costly property damage. This course reviews the plumbing codes and standards that govern plumbing fittings and fixtures, with special attention to standards to control the leaching of organics, metals, and lead into drinking water.


  • ( ~ 1 hour ) 

    Life-safety systems encompass both passive fire-protection features, like compartmentation and firestopping, and active ones, such as sprinklers and alarms. Portable fire extinguishers are an integral part of life-safety systems and must meet code-mandated number and placement requirements in most building types. This course looks at how fire extinguishers can be stored safely and securely in cabinets and addresses specification considerations. Also reviewed are the many options available to customize fire extinguisher cabinets so they are tailored to each project’s needs and design goals.


  • ( ~ 1 hour ) 

    This course explains the NFPA 285 test method, its origin, its procedures, when it is required, and design considerations necessary for compliance. Criteria in ASHRAE 90.1 for continuous insulation and air/water-resistive barriers are reviewed and identified as contributors to the rise of NFPA 285 requirements. The course also addresses code compliance in light of recent material changes, code changes, and additional testing.


  • ( ~ 1 hour, 15 minutes ) 

    Considering gate hardware early in the design process enhances the aesthetics and functionality of perimeter security. Gate hardware balances durability, security, and ease-of-use without detracting from the design. This course examines latches, plain pivot and self-closing hinges, closers and accessories for swing gates, and wheels for sliding gates; it also offers guidance on specification and installation.


  • ( ~ 1 hour, 30 minutes ) 

    Continuous insulation is part of building standards and state and energy codes due to its ability to reduce thermal bridging and the associated heat loss and energy consumption. This course looks at the use of polyisocyanurate as a continuous insulation in Type V and residential construction and its use as a multifunctional envelope component—air barrier, weather-resistive barrier, and vapor retarder—by reviewing code requirements for the building envelope.


  • ( ~ 1 hour ) 

    Bathing facility code compliance does not have to result in an institutional look. Assisted living and healthcare facilities, hospitality installations, universities, multifamily buildings, and large commercial projects all have unique demands, and most require barrier-free, ADA, UFAS, ANSI, California Title 24, or Massachusetts compliant bathing and showering facilities. This course provides an overview of intelligent design solutions that simultaneously address these code requirements and the aesthetic and functional demands of each situation.


  • ( ~ 1 hour, 30 minutes ) 

    Attic ventilation is an important component in proper structural design. By encouraging airflow, attic ventilation plays a key role in maintaining structural integrity, ensuring roof component durability, providing a healthy indoor environment, and minimizing energy consumption. Additionally, proper attic ventilation hinders or prevents mold growth, reduces interior pollutants, and acts as a pivotal fire prevention tool. This course looks at how attic ventilation systems work, the benefits they provide, and the associated building codes and regulations.


  • ( ~ 1 hour ) 

    Stairs are often a prominent feature or even the focal point of an architectural design project and play a vital role in creating an aesthetically pleasing interior atmosphere, or an exterior welcoming point to a residential, commercial, or industrial building. This course provides an overview of the many benefits of installing precast concrete stair treads and landings, how to detail and specify them, and how to address related building code, design, and construction requirements.


  • ( ~ 1 hour ) 

    The selection of windows and doors for a particular project must satisfy its aesthetic and functional requirements. However, we also want windows and doors to be safe, durable, leak-free, and energy efficient and meet the needs of those with disabilities. The International Building Code® and related standards ensure that windows and doors support public health, safety, well-being, and energy efficiency. This course provides an overview of the codes and standards for doors and windows, including weather resistance, durability, egress, safety, and accessibility requirements.


  • ( ~ 1 hour, 15 minutes ) 

    This presentation aims to aid architects, engineers, and specification writers in choosing anchoring systems to comply with the 2022 edition of The Masonry Society’s (TMS) TMS 402 Building Code Requirements for Masonry Structures and the International Building Code® (IBC®).


  • ( ~ 30 minutes ) 

    ASCE 7-16, Minimum Design Loads and Associated Criteria for Buildings and Other Structures, provides several design alternatives that architects and engineers can use to reduce the potential for either partial or progressive collapse due to extraordinary events, whether natural or man-made. The minimum design load philosophy of the building code is at odds with some extraordinary events. ASCE 7, Section 2.5, “Load Combinations for Extraordinary Events,” which is incorporated into the IBC, covers such extraordinary events, stating: “Where required by the owner or applicable code, strength and stability shall be checked to ensure that structures are capable of withstanding the effects of extraordinary (i.e., low-probability) events, such as fires, explosions, and vehicular impact without disproportionate collapse.” There are several methods for achieving added safety in both expected and extraordinary events. These include performance-based design (for expected events) and methods for design against partial or progressive collapse (for extraordinary events). In this briefing, we’ll explore methods for design against partial or progressive collapse as found in ASCE 7, Section 1.4.6, “Extraordinary Loads and Events.”


  • ( ~ 1 hour ) 

    Fire control for high-rise building facades requires active and passive systems to work in tandem. This course explains how passive fire protection systems for building envelopes should be used to create fire containment compartments to control fire spread; also addressed are the codes, standards, testing, and compliance routes that apply to verify material and system performance. The course provides detailed illustrations of how the materials must be designed and installed to create effective fire containment compartments and explains how they relate to active fire prevention systems.


  • ( ~ 1 hour ) 

    Ensuring proper use of methods and materials allows masonry walls to perform well and enjoy a long life. Use of masonry joint reinforcement and accessories is an essential part of this. This course provides a brief history of solid masonry walls leading up to the modern cavity walls of today, including a discussion of the basic working knowledge of masonry joint reinforcing, structural codes, and moisture control in cavity wall construction.


  • ( ~ 1 hour ) 

    Authorities having jurisdiction all over the world, including in all 50 US states, have mandated photoluminescent egress path markings to support safe evacuation of high-rise buildings in the case of total power failure. This course reviews photoluminescent egress path marking requirements in the model International Building Code® and International Fire Code® (2015, 2018, 2021) and identifies compliant photoluminescent path marking products. The course also discusses recommended best practices that exceed code requirements, which will reduce building operation costs and improve occupant and first responder safety.


  • ( ~ 1 hour, 15 minutes ) 

    There are a multitude of building envelope products used and a variety of methods taken for achieving energy and building code requirements. Understanding the different roles a product plays in the envelope simplifies its design. In this course, we take a look at the code requirements for buildings classified as IBC Types I–IV, paths to achieving compliance, and the number of roles polyisocyanurate insulation plays in meeting these requirements.


  • ( ~ 1 hour ) 

    Railing systems perform various functions, meeting safety requirements and serving as a key component of a building’s aesthetic. This course includes a discussion of the strengths and weaknesses of aluminum and structural vinyl railing systems, how they are made, and how they are used in the building industry, including a detailed summary of how they meet various code requirements.


  • ( ~ 1 hour ) 

    Fire safety is an important building enclosure design factor and needs to be addressed hand-in-hand with energy code requirements. NFPA 285 is a critical consideration with modern building assemblies incorporating combustible materials in noncombustible construction. This presentation reviews the history and scope of the NFPA 285 test standard and its adoption into the International Building Code® (IBC®). The compliance criteria are outlined, and triggers and contributors under the standard are identified. The course also reviews how the selection of building components such as insulation, air-/water-resistive barriers, and claddings affects the fire performance of an assembly, and solutions and common paths for compliance are presented.


  • ( ~ 1 hour ) 

    Building fires claim nearly 4,000 lives each year in the U.S. It is the responsibility of building designers to do their utmost to prevent such fires and their accompanying loss of life. Often, the difference between life and death is as simple as a fire door that functions properly. This course focuses on describing how design professionals can reinforce their ability to ensure that fire doors are specified, installed, inspected, and maintained properly and that they meet or exceed all relevant code requirements.


  • ( ~ 1 hour ) 

    Multifamily Group R construction has traditionally been access controlled by means of pin and tumbler mechanical locks. With the migration to electronic access control locks, it can be complicated to understand how to comply with building and fire codes. This course attempts to demystify electronic access control by addressing the basic components, important terms, and design and code considerations, and concludes with a look at a case study.


  • ( ~ 1 hour ) 

    This introductory course is designed to educate all attendees on the most common types and configurations of multifamily buildings. In addition, each attendee will gain access to common manufacturing details associated with multifamily work and how to properly size engineered wood products. Two methods of design are reviewed using specific manufacturer literature and software that is available from all manufacturers and third-party sources.


  • ( ~ 1 hour ) 

    The increase in building energy efficiency requirements has led to the use of exterior continuous insulation (CI) to improve the performance of the building envelope. This presentation reviews the benefits of polyiso continuous insulation and then examines in detail the NFPA 285 test standard and fire safety requirements of the 2021 International Building Code for the use of polyisocyanurate insulation in exterior walls of commercial buildings (Construction Types I–IV).


  • ( ~ 1 hour, 15 minutes ) 

    Energy codes at the federal, state, and local levels increasingly focus on reducing energy consumption, saving consumers money, and reducing CO2 emissions. Whether new or recently updated, energy codes play an essential role in the buildings we design, build, and ultimately live, work, and play in. This course examines the lighting requirements and provisions of ASHRAE Standard 90.1-2019 and the 2021 International Energy Conservation Code ® , with a focus on plug and lighting control strategies for energy efficiency.


  • ( ~ 1 hour ) 

    With limited exceptions, the International Building Code® (IBC®) requires testing and compliance with NFPA 285 for exterior wall assemblies of buildings of Types I, II, III, and IV construction containing foam plastic insulation. This course examines three methods for demonstrating that an exterior wall assembly design complies with NFPA 285, including engineering analysis. The course also discusses how and where to locate NFPA 285 information for each compliance method.


  • ( ~ 1 hour ) 

    Single-family attached residences (residences that share one or more walls between neighbors) are required to utilize area separation walls between units. A key design criterion of any firewall—besides its fire rating—is that it be structurally independent in a fire. This course evaluates two-hour fire-resistance-rated walls used in single-family attached and multifamily residential construction, the options available in today’s marketplace, firewall installation requirements, and fire-resistance testing.

Displaying 1 - 24 of 24 results.